CheckPFAS

ZIP Code 34470

High Risk
High Risk PFAS Risk Level

PFAS above EPA limits detected

5 compounds exceed EPA Maximum Contaminant Levels in water serving this ZIP code. Standard pitcher filters like Brita do not remove PFAS. See filter recommendations below.

15
PFAS Detected
5
Above EPA Limits
2
Water Systems
975%
Highest % of MCL

Compounds Exceeding EPA Limits

PFOS Exceeds EPA limit
0 ppt MCL: 4 ppt 975% of limit
Detected: 39.00 ppt
PFHxS Exceeds EPA limit
0 ppt MCL: 10 ppt 420% of limit
Detected: 42.00 ppt
PFOA Exceeds EPA limit
0 ppt MCL: 4 ppt 163% of limit
Detected: 6.50 ppt

OCALA, CITY OF (2 WTPS)

FL3420922 High Risk
Water Type
Groundwater
PFAS Detected
9
Above MCL
3
State
Florida
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOS
Perfluorooctane sulfonic acid
39.00ppt
975% of limit
4 ppt⚠ Exceeds MCL
PFHxS
Perfluorohexane sulfonic acid
42.00ppt
420% of limit
10 ppt⚠ Exceeds MCL
PFOA
Perfluorooctanoic acid
6.50ppt
163% of limit
4 ppt⚠ Exceeds MCL
PFPeA
Perfluoropentanoic acid
14.00pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
12.00pptNo federal limitUnregulated
PFBS
Perfluorobutane sulfonic acid
8.50pptNo federal limitUnregulated
PFPeS
6.40pptNo federal limitUnregulated
PFHpA
Perfluoroheptanoic acid
6.30pptNo federal limitUnregulated
Show 1 more compound detected at low levels
PFBAPerfluorobutanoic acid5.80 pptNo federal limit

OCALA HEIGHTS S/D

FL3424651 High Risk
Water Type
Groundwater
PFAS Detected
6
Above MCL
2
State
Florida
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOS
Perfluorooctane sulfonic acid
6.40ppt
160% of limit
4 ppt⚠ Exceeds MCL
PFOA
Perfluorooctanoic acid
6.20ppt
155% of limit
4 ppt⚠ Exceeds MCL
PFHxS
Perfluorohexane sulfonic acid
4.30ppt
43% of limit
10 pptBelow limit
PFBS
Perfluorobutane sulfonic acid
5.80pptNo federal limitUnregulated
PFPeA
Perfluoropentanoic acid
5.50pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
4.20pptNo federal limitUnregulated
Note: ZIP code 34470 is served by 2 separate water utilities. Results above show data for each system independently.

Data source: EPA Unregulated Contaminant Monitoring Rule, 5th cycle (UCMR 5) — January 2026 release.

UCMR 5 tested ~10,000 public water systems serving more than 25 people between 2023-2025 for 29 PFAS compounds.

Detection values represent the highest single-sample result measured at entry points to the distribution system.

View raw EPA data →