CheckPFAS

ZIP Code 35146

High Risk
High Risk PFAS Risk Level

PFAS above EPA limits detected

2 compounds exceed EPA Maximum Contaminant Levels in water serving this ZIP code. Standard pitcher filters like Brita do not remove PFAS. See filter recommendations below.

10
PFAS Detected
2
Above EPA Limits
2
Water Systems
123%
Highest % of MCL

Compounds Exceeding EPA Limits

PFOA Exceeds EPA limit
0 ppt MCL: 4 ppt 123% of limit
Detected: 4.90 ppt

ODENVILLE (UTIL BOARD OF THE TOWN OF)

AL0001203 High Risk
Water Type
Surface Water
PFAS Detected
5
Above MCL
1
State
Alabama
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOA
Perfluorooctanoic acid
4.90ppt
123% of limit
4 ppt⚠ Exceeds MCL
PFBS
Perfluorobutane sulfonic acid
24.30pptNo federal limitUnregulated
PFPeA
Perfluoropentanoic acid
17.60pptNo federal limitUnregulated
PFBA
Perfluorobutanoic acid
10.00pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
8.40pptNo federal limitUnregulated

SPRINGVILLE WATER WORKS

AL0001211 High Risk
Water Type
Surface Water
PFAS Detected
5
Above MCL
1
State
Alabama
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOA
Perfluorooctanoic acid
4.10ppt
103% of limit
4 ppt⚠ Exceeds MCL
PFBS
Perfluorobutane sulfonic acid
36.00pptNo federal limitUnregulated
PFPeA
Perfluoropentanoic acid
27.10pptNo federal limitUnregulated
PFBA
Perfluorobutanoic acid
13.30pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
11.40pptNo federal limitUnregulated
Note: ZIP code 35146 is served by 2 separate water utilities. Results above show data for each system independently.

Data source: EPA Unregulated Contaminant Monitoring Rule, 5th cycle (UCMR 5) — January 2026 release.

UCMR 5 tested ~10,000 public water systems serving more than 25 people between 2023-2025 for 29 PFAS compounds.

Detection values represent the highest single-sample result measured at entry points to the distribution system.

View raw EPA data →