CheckPFAS

ZIP Code 78621

High Risk
High Risk PFAS Risk Level

PFAS above EPA limits detected

3 compounds exceed EPA Maximum Contaminant Levels in water serving this ZIP code. Standard pitcher filters like Brita do not remove PFAS. See filter recommendations below.

13
PFAS Detected
3
Above EPA Limits
3
Water Systems
310%
Highest % of MCL

Compounds Exceeding EPA Limits

PFOS Exceeds EPA limit
0 ppt MCL: 4 ppt 310% of limit
Detected: 12.40 ppt
PFNA Exceeds EPA limit
0 ppt MCL: 10 ppt 243% of limit
Detected: 24.30 ppt
PFOA Exceeds EPA limit
0 ppt MCL: 4 ppt 148% of limit
Detected: 5.90 ppt

CITY OF ELGIN

TX0110002 Low Level
Water Type
Groundwater
PFAS Detected
1
Above MCL
0
State
Texas
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
lithium
36500.00pptNo federal limitUnregulated

AQUA WSC

TX0110013 Low Level
Water Type
Groundwater
PFAS Detected
1
Above MCL
0
State
Texas
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
lithium
83000.00pptNo federal limitUnregulated

MANVILLE WSC

TX2270033 High Risk
Water Type
Groundwater
PFAS Detected
11
Above MCL
3
State
Texas
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOS
Perfluorooctane sulfonic acid
12.40ppt
310% of limit
4 ppt⚠ Exceeds MCL
PFNA
Perfluorononanoic acid
24.30ppt
243% of limit
10 ppt⚠ Exceeds MCL
PFOA
Perfluorooctanoic acid
5.90ppt
148% of limit
4 ppt⚠ Exceeds MCL
PFHxS
Perfluorohexane sulfonic acid
7.00ppt
70% of limit
10 pptBelow limit
lithium
83800.00pptNo federal limitUnregulated
PFBS
Perfluorobutane sulfonic acid
10.00pptNo federal limitUnregulated
PFPeA
Perfluoropentanoic acid
9.10pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
8.70pptNo federal limitUnregulated
Show 3 more compounds detected at low levels
PFBAPerfluorobutanoic acid7.40 pptNo federal limit
PFHpAPerfluoroheptanoic acid4.30 pptNo federal limit
PFUnAPerfluoroundecanoic acid2.70 pptNo federal limit
Note: ZIP code 78621 is served by 3 separate water utilities. Results above show data for each system independently.

Data source: EPA Unregulated Contaminant Monitoring Rule, 5th cycle (UCMR 5) — January 2026 release.

UCMR 5 tested ~10,000 public water systems serving more than 25 people between 2023-2025 for 29 PFAS compounds.

Detection values represent the highest single-sample result measured at entry points to the distribution system.

View raw EPA data →