CheckPFAS

CANNON AIR FORCE BASE WATER SYSTEM

High Risk
PWSID: NM3567905 New Mexico Groundwater

1 PFAS compound(s) exceed EPA Maximum Contaminant Levels

This utility has until 2029 to install treatment under the EPA's April 2024 PFAS rule. In the meantime, a point-of-use filter certified NSF/ANSI 58 for PFOA/PFOS provides reliable interim protection.

8
PFAS Detected
1
Above EPA Limits
1
ZIP Served
Groundwater
Water Source

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFHxS
Perfluorohexane sulfonic acid
17.70ppt
177% of limit
10 ppt⚠ Exceeds MCL
lithium
111000.00pptNo federal limitUnregulated
PFPeA
Perfluoropentanoic acid
42.00pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
28.00pptNo federal limitUnregulated
PFBA
Perfluorobutanoic acid
20.00pptNo federal limitUnregulated
PFBS
Perfluorobutane sulfonic acid
15.00pptNo federal limitUnregulated
PFPeS
6.10pptNo federal limitUnregulated
PFHpA
Perfluoroheptanoic acid
6.00pptNo federal limitUnregulated

ZIP Codes Served by This Utility

Click any ZIP to see the full result page for that area.

About this data
Source
EPA UCMR 5 — January 2026 release
Sampling period
January 2023 – December 2025
Water system ID (PWSID)
NM3567905
Detection threshold (MRL)
~1.5–2 ppt — "Not detected" means below this floor